- 2 minutes to read

AllowResubmit - System Parameter

AllowResubmit is the master switch for resending logged messages (Log Events) from Log Views in the Web Client. When it is false, nobody can Resend or Repair, whatever their Role permissions say.

At a Glance

Property Value
Key AllowResubmit
Data type boolean
Default true (Resend allowed)
Read by Web Client
Takes effect Within about 15 seconds; no restart needed
Status ✅ Active
Since Nodinite 3

How It Works

A user can Resend a Log Event when both of these hold:

# Setting Where
1 AllowResubmit = true This System Parameter (global)
2 Allow Resend permission on the Log View The user's Role, see Resend in Permission Set for Log Views

Repair builds on Resend: it additionally needs AllowRepair = true and the Allow Repair permission. Setting AllowResubmit to false therefore turns off Repair too, and AllowRepair then has no effect. The AllowRepair page shows the full decision flow.

Repair can send the message to a Webhook or to ActiveMQ, among other transports; ResendWebhookSettings and ResubmitContextValuesForActiveMQ configure those targets.

Choosing a Value

  • Keep true (default) and control who may resend with the Allow Resend permission per Log View, see Add or Manage Log View.
  • Set false to stop all resends at once, for example in an environment where nothing must be sent again.

Next Steps