- 6 minutes to read

Manage System Parameters

This guide shows how an administrator changes a System Parameter value in Nodinite — in the Web Client or through the Web API — and what happens after you save. Each environment has its own set of values, stored in its Configuration Database (see where the values are stored).

Changing ArticleStaleDays from 180 to 365 in the Web Client: filter the System Parameters list, open the key, enter the new value, Save and close, filter again, and the list shows 365, animated walkthrough (7.12)
Animated walkthrough: filter the list on ArticleStale, open ArticleStaleDays, enter 365, click Save and close, and filter again: the list shows the new value.

Before You Change a Value

  • Read the parameter's page first. Each page in the System Parameters list states the data type, the default, which service reads the value, and when a change takes effect.
  • No restart needed. Every Nodinite process caches each value for about 15 seconds. A few parameters wait for the next cleanup or processing run, or use a longer cache; the parameter page says so.
  • Note the old value. A wrong value can stop logging or monitoring. Write down the current value so you can put it back.
  • Administrator role required. You must be a member of the built-in Administrator Role to change a value, both in the Web Client and through the Web API.

Data Types

The edit page shows each parameter's data type below the value, and the type decides how you enter it.

Data type Enter Example
boolean Two radio buttons, true and false true
integer / double A number box; enter the number in the unit the parameter page states (days, GB, MB, milliseconds, …) 90
string A text box; some parameters use a semicolon-separated list or a pattern Administrators;Operators
json A text box with a valid JSON value, following the structure on the parameter page {"MaxRetries":3,"TimeoutSeconds":120}

Change a Value in the Web Client

Step 1: Open System Parameters

In the Web Client, go to Administration › Settings › System Parameters. The list shows every key with its description and current value. Type in Filter the result to narrow the list by key, description, or value; click a column header to sort.

System Parameters list filtered on Allow, with the Key, Description, and Value columns and the AllowExport, AllowRepair, AllowRepositoryAutomapping, and AllowResubmit rows (7.12)
The System Parameters list, filtered on Allow.

Step 2: Edit the Value

  1. Click the key you want to change. Its edit page opens with the Key, the product's Description, the Value, and the Data type.
  2. Enter the new value in Value.
  3. For a json parameter, the page checks the JSON as you type. A syntax error shows Json syntax is not correct! and blocks saving. Then one of three results shows:
    • Json model is valid (green): the value fits the parameter's structure.
    • Json invalid. Error message: … (red): the value doesn't fit, and saving is blocked.
    • Json validation for this System Parameter has not been implemented (yellow): the parameter has no validator; you can still save, so check the value against the parameter page.
  4. Click Save to stay on the page (it shows Successfully saved the changes), or Save and close to go back to the list. Save is also in the page toolbar, top right next to the title. Both Save buttons stay disabled until the value changes, and while a validation error blocks the value. Once you change the value, Close reads Cancel.

If Nodinite refuses the value on Save, the page shows the reason, for example Value for system parameter 'MessageProcessingMaxBodySize' must be 1 or higher (MB). 0 is not allowed.

Edit page of the AlarmQueueSettings System Parameter with the breadcrumb, the disabled Save in the page toolbar, Key, Description, the JSON value, Json model is valid, Data type json, and the disabled Save and Save and close and the Close button below the form (7.12)
The edit page: key, description, value, the JSON check result, the data type, and the buttons. Nothing has changed yet, so both Save buttons are disabled.

Important

"Json model is valid" means the JSON matches the expected structure. It does not prove that every value is sensible — check the parameter page. Some validators only check the shape: unknown or misspelled properties are ignored.

Note

To clear a string or json value, empty Value and click Save. An empty json value shows no JSON check. A parameter that needs a value (for example the true/false keys, SharedFilePolicy, and ArticleSecurityPolicy) is refused on Save, with the reason.

Step 3: Verify the Change

Wait until the change takes effect (see the parameter page), then check the behaviour it controls: for example a new retention value on the next cleanup run, or the header colour after a page refresh for EnvironmentColor.

Read-Only and Special Keys

Key How to change it
ProductKey, CustomerName 🔒 Read-only here: the key isn't a link, the page says This system parameter can not be modified from here, and the value is never shown. Change them in Manage License.
Version Set by the installer. The Web Client lets you edit it, but don't change it.
EnvironmentName, SqlServer, ProductArtifactsPath Set during installation. Change them only when Support asks you to.
AI The key opens the typed AI Settings page instead of the raw edit page.
AllowExport ❌ Obsolete; changing it has no effect.
MessageProcessingTimerInterval ❌ Removed in 7.12; the update deletes the key.

Change a Value Through the Web API

Automation and deployment scripts can change values through the Web API; for authentication and the base URL, see System Parameters in Managing the Web API. Explore the operations in Scalar at the root of the Web API site (https://{host}:{port}/scalar).

Operation What it does
PUT api/SystemParameters/{key} Changes the value of {key}. Requires the Administrator role. Changes only the value; the description and data type stay as they are. New 7.12 A {key} that doesn't exist answers 404 Not Found, and nothing is saved.
POST api/SystemParameters/{key}/ValidateJson Validates a JSON value for {key} without saving it. Works for the json parameters that have a validator; other keys return not implemented.

Warning

The PUT operation validates only some keys: it checks AI, ArticleSecurityPolicy, LogEventsPerDayThresholds, ResendWebhookSettings, ServiceBusRelayHostSuffixes, and SharedFilePolicy, the boolean and integer keys, and LogDatabaseRecovery, and it refuses CustomerName and ProductKey. It does not validate the other json keys (for example AlarmQueueSettings, LogLocations, DatabaseMaintenance). Call ValidateJson first, or test the value in the Web Client, before you script a change to a json parameter. A refused value answers 400 (Bad Request) with the reason in Collection.Error.Message, the same text the edit page shows, for example Value for system parameter 'MessageProcessingMaxBodySize' must be 1 or higher (MB). 0 is not allowed. A 500 Failed to edit System Parameter means an unexpected error, not a refused value.

Frequently Asked Questions

Do I need to restart any service after a change?

No. In Nodinite v7 no System Parameter needs a restart. Each parameter page states how soon its change takes effect.

Where are the values stored?

In the SystemParameters table of the Configuration Database, one row per key. Change values through the Web Client or the Web API, not directly in SQL Server, so that the Administrator role is checked and JSON can be validated first.

I use Nodinite v6. Do these steps apply?

No. Nodinite v6 used the Install and Update Tool, which is no longer supported. Upgrade to Nodinite v7 to manage System Parameters in the Web Client.

Next Steps