- 1 minutes to read

MessageProcessingTimerInterval - System Parameter

MessageProcessingTimerInterval was removed in Nodinite 7.12. It once set how often the Logging Service looked for new messages to process; in v7 it had no effect, because the processing intervals are fixed. The 7.12 update deletes the key, so it no longer appears in System Parameters.

At a Glance

Property Value
Key MessageProcessingTimerInterval
Data type integer (milliseconds)
Default 15000 (ignored)
Read by Nothing; the Logging Service uses fixed intervals
Status ❌ Removed in 7.12: the update deletes the key. Up to 7.11 it was shown with ⚠️ No effect

What to Use Instead

Nothing; there is no message processing interval to tune. The Logging Service checks the active Log Database for new messages every 30 seconds and the archive Log Databases every 5 minutes. These intervals are hard-coded. See Message Processing on the Logging Service page.

Each check processes the whole backlog, batch by batch. To control how much message data the Logging Service holds in memory per batch, use MessageProcessingBatchSize; to skip very large messages, use MessageProcessingMaxBodySize.