- 2 minutes to read
Release Notes
MSMQ Configuration Example
On this page you will learn how to configure the Nodinite Pickup Logging Service to fetch Nodinite JSON Log Event from an MSMQ queue.
graph TD
subgraph "MSMQ"
roS(fal:fa-list Queue)
roBO(fal:fa-trash-can Backout queue)
end
subgraph "Nodinite instance"
roPS(fal:fa-truck-pickup Pickup Service)
roPS -.->|Bad/invalid messages| roBO
roS --> roPS
roPS --> |Long term storage|roDB(fal:fa-database Log Database)
end
MSMQs
The MSMQs section is where you manage MSMQ Queue related sources.
The configuration file (Settings.json
), is in JSON format, the default path is:
C:\Program Files\Nodinite\Logging Agent - Pickup Service\Settings.json
{
...
"MSMQs": [
{
"Enabled": true,
"LogApi": "https://localhost/Nodinite/Dev/LogAPI/",
"UseConfigurationDatabase": false,
"ConfigurationDatabaseConnectionString": null,
"ActiveConsumers": 4,
"Server": "localhost",
"Queue": "Nodinite.LogAgent.PickupService.Test",
"DeadLetterQueue": "Nodinite.LogAgent.PickupService.Test.DLQ",
"ReplaceRules": [
{
"Name": "Fix Endpoint real customer id to {customerId}",
"ReplaceName": false,
"ReplaceUri": true,
"Pattern": "/([0-9]{4,})$",
"Group1Value": "{customerId}"
}
]
}
]
...
}
Folders is an array of a Folder configuration. Each configuration is valid for one Folder. This configuration tells the Log Agent where to look for log messages with the Nodinite JSON Log Events.
Property | Description | Value Example | Comment |
---|---|---|---|
ActiveConsumers | Number of consumers that the agent will use to collect messages | 1-n | Use any positive integer, between 1 and 4 is recommended |
Server | The name of the Windows server with MSMQ | ||
Queue | The name of the MSMQ Queue from where to pickup JSON Log Event from | NOTE: Only the name of the queue | |
DeadLetterQueue | The name of the specific Dead letter queue where the pickup service will put invalid events and/or events that can't be logged | ||
Enabled | Review the Shared Configuration section for additional information | ||
LogAPI | Review the Shared Configuration section for additional information | ||
UseConfigurationDatabase | Review the Shared Configuration section for additional information | ||
ConfigurationDatabaseConnectionString | Review the Shared Configuration section for additional information | ||
ReplaceRules | Review the shared Replace Rules section for additional information |
Important